Home Print this page Email this page Small font size Default font size Increase font size   Users Online: 100
Home About us Editorial board Search Browse articles Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 7  |  Issue : 1  |  Page : 17

Accuracy and reliability of tooth length measurements on conventional and cbct images: An in vitro comparative study


Department of Orthodontics and Dentofacial Orthopedics, I.T.S. Dental College, Muradnagar, Affiliated from Chaudhary Charan Singh University, Ghaziabad, Uttar Pradesh, India

Correspondence Address:
Dr. Kumar Adarsh
S/o Dr. Anjani Kumar Sinha, House No-11, Road No-5, East Patel Nagar, Patna - 800 023, Bihar
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jos.JOS_21_18

Rights and Permissions

CONTEXT: The purpose of this study was to evaluate the accuracy and reliability of tooth length measurements using conventional and cone-beam computed tomography (CBCT) imaging techniques. AIM: The aim of this study was to assess the accuracy and reliability of various tooth length measurements made on CBCT scans and conventional imaging techniques [intraoral periapical radiograph (IOPA) and orthopantomogram (OPG)]. SETTINGS AND DESIGN: This is an in-vitro comparative study. SUBJECTS AND METHODS: In total, 50 extracted single-rooted premolar teeth were mounted on the dry human mandible. For each extracted tooth, measurements for tooth length, crown length, and root lengths were taken with a Vernier caliper and using three imaging modalities: CBCT, OPG, and IOPA radiographs. The measurements were compared with the gold standard (Vernier caliper). STATISTICAL ANALYSIS USED: One-way analysis of variance was used to compare mean values between the groups that are Vernier caliper, CBCT, IOPA, and OPG. The multiple comparisons of means of tooth length, root length, and crown length were done by Bonferroni test. RESULTS: A significant difference in the tooth length measurements was seen between the measurements taken by CBCT and IOPA and between IOPA and OPG. But, no significant difference was seen between any other groups. The highly significant difference was seen between the root length measurements taken by IOPA and OPG and by CBCT and OPG. However, no significant difference was seen between any other groups. No significant difference was seen in between the crown length measurements taken by Vernier caliper and CBCT and between IOPA and OPG. However, a significant difference was seen between all the groups. CONCLUSIONS: Among the radiographic techniques, CBCT was found to be the most accurate in measuring the tooth, root, and crown lengths.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed380    
    Printed29    
    Emailed0    
    PDF Downloaded112    
    Comments [Add]    

Recommend this journal