Home Print this page Email this page Small font size Default font size Increase font size   Users Online: 205
Home About us Editorial board Search Browse articles Submit article Instructions Subscribe Contacts Login 


 
 Table of Contents  
SHORT COMMUNICATION
Year : 2015  |  Volume : 4  |  Issue : 1  |  Page : 30-32

The Begg's uprighting spring - Revisited


1 Oral Health Sciences Center, Post Graduate Institute of Medical Education and Research, Chandigarh, India
2 Department of Orthodontics, Govt. Dental College, Calicut, India

Date of Web Publication19-Jan-2015

Correspondence Address:
Vinay Kumar
Unit of Orthodontics, Oral Health Sciences Center, Post Graduate Institute of Medical Education and Research, Chandigarh 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions
  Abstract 

Uprighting springs, an integral part of the Begg ligsht wire differential force technique is gaining more and more popularity, as a useful adjunct in contemporary preadjusted edgewise appliance systems as well. It can be used with brackets containing vertical slots for mesiodistal crown uprighting, or as braking auxiliaries providing additional anchorage while protracting posteriors. Here, we present a simple and quick chair side method of fabricating and customizing uprighting springs according to the required crown/root movement for correction. This communication would serve as a ready reckoner during fabrication of the springs, thus dispelling the confusion that usually arises regarding direction and position of the coil and active arm.

Keywords: Braking mechanics, reinforced anchorage, root uprighting


How to cite this article:
Kumar V, Sundareswaran S. The Begg's uprighting spring - Revisited . J Orthodont Sci 2015;4:30-2

How to cite this URL:
Kumar V, Sundareswaran S. The Begg's uprighting spring - Revisited . J Orthodont Sci [serial online] 2015 [cited 2020 Nov 29];4:30-2. Available from: https://www.jorthodsci.org/text.asp?2015/4/1/30/149615


  Introduction Top


Uprighting springs or mesiodistal root uprighting springs are an indispensable component of light wire differential force technique, introduced by  Begg in 1956. [1] Besides being used for mesiodistal root uprighting during Stage III of Begg's Technique, [1] they are also used as braking auxiliaries to increase the anchorage to carry out various tooth movements. [1],[2],[3] However, with the advent of the preadjusted edgewise appliance, the use of light wire technique has drastically reduced resulting in a lack of familiarization of the Begg uprighting spring among contemporary orthodontists. Of late, the various possibilities of this spring as an adjunctive in contemporary preadjusted edgewise appliance systems containing vertical slot is being explored. The additional anchorage potential provided by uprighting springs can be used to treat different situations successfully (e.g. space closure by posterior teeth protraction). [3] These springs are made from 0.009" to 0.018" Australian archwire depending upon the type of tooth (i.e. incisors, canines, premolars and molars) and the purpose (e.g. mesiodistal uprighting or as brakes to provide additional anchorage) for which we need to use these auxiliaries. [4] Although these uprighting springs are easily available in prefabricated form, here we present a simple and quick chair side method to fabricate and customize uprighting springs according to the required crown/root movement for correction.


  Steps in fabrication Top


  1. Determine the type of moment (clockwise or counterclockwise), required for mesiodistal root uprighting either clinically or with the help of OPG. This will vary depending upon tooth type and quadrant of the arch under consideration in the maxilla or mandible.
  2. [Figure 1], represents a situation, where upper right 2 nd premolar needs clockwise moment for root uprighting.
  3. Hold approximately 6 cm of Australian arch wire, as shown in Figure 1a, and bend the right plank of the wire in a clockwise direction. Then, the wire is bent around beak of 139 pliers keeping this end under the left plank [Figure 1]b. Make the coil with two and half turns [Figure 1]c. Figure 1d completes the residual wire bending as per requirement of the degree of activation.

    Optimum angulation is 135° between arm and stem of uprighting spring. For anchorage reinforcement, minimum to moderate degree of activation is sufficient. This will also minimize side effects on adjacent teeth.
  4. [Figure 2], represents a situation, where lower right 2 nd premolar needs anticlockwise moment for root uprighting [Figure 2]a. Bend the left plank of wire in anticlockwise direction. In [Figure 2]b, the wire is bent around beak of 139 pliers keeping this end under the right plank. Give two and a half turns around the beak [Figure 2]c. Complete the residual wire bending required at activation arm and stem of uprighting spring that is anticlockwise type [Figure 2]d.
Figure 1: Step by step procedure to fabricate clockwise type uprighting spring. (a) Hold the Australian wire in 139 pliers showing required direction of the bend; (b) Bend the right plank of wire in a clockwise direction, keeping this end under left plank; (c) Make two and half turns and (d) Complete the residual wire bending and final clockwise type uprighting spring

Click here to view
Figure 2: Step by step procedure to fabricate anticlockwise type uprighting spring (a) Hold the Australian wire in 139 pliers showing required direction of the bend; (b) Bend the left plank of wire in anticlockwise direction, keeping this end under right plank, (c) Make two and half turns and (d) Complete the residual wire bending and final anticlockwise type uprighting spring

Click here to view


Alternatively, bending directly from the spool is advisable to prevent wastage. Springs should always be used with rigid base archwires.


  Discussion Top


Contemporary world of orthodontics utilizes different kinds of preadjusted appliances, where all the features to correct 1 st , 2 nd and 3 rd order discrepancies, are incorporated therein. However, certain clinical situations exist where we need to increase or reinforce the anchorage value at a particular location, to carry out various types of orthodontic tooth movements. Some of these clinical situations are shown in Figure 3, where Begg's uprighting spring has been used as an adjunct to facilitate tooth movements. Barbieri and Barbieri [3] reported various clinical situations for the use of uprighting spring to reinforce anchorage.

These auxiliaries can also be useful in diverging the roots of canines and or first premolars in presurgical orthodontics for anterior maxillary osteotomy by Wassmund's or Wunderer's technique. Physical factors like gauge and resiliency of the wire, size of the helix, number of the coils, direction of activation [3] are discussed besides their classical use as mesiodistal uprighting auxiliary. [1],[2],[3],[4] The relationship between diameter of the wire and diameter of the loop referred to as "spring coil index" should be at least six as described by Thurow. [5],[6] This means that loop diameter should be at least 6 times the diameter of the wire (e.g. for wire diameter of 0.012", loop diameter should be 0.072") for its optimal performance. Lesser than this will lead to the creation of internal strain and increases the risk of failure. [6] So also, while using such kind of auxiliaries, the utmost care must be exercised to prevent or minimize their side effects like labial crown movements, extrusion of anteriors, intrusion of posteriors and buccal crown movements. It is, therefore, absolutely essential that the base archwire be rigid enough, preferably 0.020" premium or 0.018" premium plus, pulse straightened Australian archwires to overcome the side effects.


  Summary Top


A simple and quick method to fabricate uprighting spring has been described here. This can find use to enhance uprighting (quality and quantity), reinforce anchorage, and presurgical root positioning along with contemporary preadjusted edgewise (or Tip-edge type) appliances. Merely determining the direction (clockwise or anticlockwise) of moments, will help to customize these uprighting springs as per individual needs as shown in [Figure 3]. Additional advantages are that there is no need for stocking/storing, or any extra investment over the purchase of prefabricated ones.
Figure 3: Various uses of Begg's uprighting spring in different clinical situations (a) Stage III of Begg's technique as uprighting of canine and premolars (b) Shows uprighting spring acting as Braking auxiliary to protract lower posterior segment; (c) and (ssd) Uprighting spring on upper left and right canine respectively with preadjusted edgewise appliance bracket

Click here to view


 
  References Top

1.
Begg PR. Differential force in orthodontic treatment. Am J Orthod 1956;42:38-48.  Back to cited text no. 1
    
2.
Cadman GR. A vade mecum for the Begg technique: Technical principles. Am J Orthod 1975;67:477-512.  Back to cited text no. 2
    
3.
Barbieri AE, Barbieri FR. Begg auxiliaries. An evaluation and clinical application. J Clin Orthod 1972;6:133-42.  Back to cited text no. 3
    
4.
Jayade VP. Refined Begg for Modern Times. 1 st ed. Karnataka: Mrs. Anuradha V. Jayade; 2001.  Back to cited text no. 4
    
5.
Wilcock AJ Jr. Arthur J. Wilcock Jr. On orthodontic wires. Interview by R. C. Kesling and C. K. Kesling. J Clin Orthod 1988;22:484-9.  Back to cited text no. 5
    
6.
Thurow CR. Edgewise Orthodontics. 4 th ed. St. Louis: C.V. Mosby; 1982. p. 252.  Back to cited text no. 6
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Steps in fabrication
Discussion
Summary
References
Article Figures

 Article Access Statistics
    Viewed3641    
    Printed69    
    Emailed0    
    PDF Downloaded588    
    Comments [Add]    

Recommend this journal